Flow Meter Method

Constraints

In practice, the flow rate, is the most difficult to determine accurately. Many pumps do not have accurate, individual flow meters, which are high cost items, especially for larger diameter pipes, and can be difficult or impossible to
install, maintain, and carry out calibration checks on-site.

 

Flow meter accuracy can be dependent on installed straight, clear pipe lengths prior to and after the measuring device, the pump’s operating point and other factors, such as build-up of debris in pipes or on sensors. Often, just the total flow from the station, or from each group of pumps, is measured.

 

Pipe installations are often compromised in the interest of minimising civil costs. Conventional flow meters, either installed or strap-on, are likely to have an accuracy of 5 to 10%, and this will lead to corresponding errors in the pump efficiency and Energy / Quantity measurements. These errors are so large that the method is impracticable for accurate measurements of energy savings, or for pump refurbishment or system control decisions.