Thermodynamic Method
About
Case Studies and Examples
The thermodynamic method can continuously measure the efficiency of raw or clean water pumps and is in extensive use in Water Utilities, and other market sectors where the fluid is water. The differential temperature across the pump is usually measured to an accuracy of about 0.001 or 0.002 °C, and the temperature probes have to be sited to ensure adequate mixing of the water, and to avoid recirculation.
Each temperature probe has two independently operating temperature sensors to identify any significant discrepancy. A feature our competitors do not have.
Our thermodynamic is our most refined and accurate measurement, however there are system limitations. Suitable systems and applications are below.
Pump Types
Fluid Types

MicroPM in Australia
-
Horizontal
-
Vertical turbine
-
High or low power (we have tested from 2 kW to 8 MW)
-
Fixed or variable speed
-
Minimum head is about 5m for good accuracy
Benefits
•Water
•Sea Water
•Air (blowers)
•Transformer oil
•Caustic liquor
•Other chemicals
•Slurries
-
Our most accurate on-site measurements
-
Pumps have individual flow meters
-
Equipment is relatively easily installed
-
Minimum disruption to operations
-
Well-characterised uncertainties
-
Calibration can be checked on-site
-
Lower cost than alternatives for retrofitting to existing pump stations
-
Low construction and pipe work costs for new pump stations
Used in
-
Portable monitors (P22™)
-
Continuous condition monitoring (MicroPM™)

Not suitable for:
· Where the suction water is not adequately mixed, or temperature is unstable
· Where there is significant recirculation to suction
· Difficulty in inserting temperature probes in appropriate positions (as for example, in desalination plants, which have many design constrants that impede accurate pump monitoring)
· Wastewater pumps - potential damage to and ragging of probes; very rapid temperature excursions
· Large vertical turbines - insufficient mixing of water as it enters the bellmouth
· Deep borehole pumps - not possible to measure suction temperature
For the above please look at our Trivimetric method.